Capture & Detection Settings

Setting
Range
Default
Description

Capture Distance

125–1000mm (5–39 in)

250mm (10 in)

Distance from sensor that triggers a capture. Objects crossing this threshold will close the door.

Pre-Capture Alerts

On/Off

On

Sends an alert when an animal enters the detection zone (before capture). Includes a 2-minute cooldown between alerts.

Detection Zones Explained

OcuTrap uses two detection zones to verify captures and reduce false triggers:

  • Detection Zone: 300–450mm from sensor — Object must show 3+ consecutive valid readings here first

  • Capture Zone: 0–250mm from sensor — Final trigger point that closes the door

This dual-zone system prevents false triggers from rain, debris, or quick movements.


Camera Settings

Setting
Range
Default
Description

Camera Time Lapse

0–24 hours

6 hours

How often the camera takes periodic photos while armed. Set to 0 to disable timelapse.

Camera Quality

1–6

2

Image resolution size (1=QVGA smallest, 6=UXGA largest). Higher = better quality but more data/power.

Rotate Image

0°, 90°, 180°, 270°

Rotates captured images. Useful if trap is mounted in non-standard orientation.

Dark Lux Threshold

1–100 lux

25 lux

Light level below which the environment is considered "dark" and IR lighting activates.

Minimum IR Brightness

0–100%

10%

Minimum infrared LED brightness in dark conditions.

Maximum IR Brightness

0–100%

100%

Maximum infrared LED brightness. Lower values reduce glare and save power.

Camera Quality Levels

Level
Resolution
Best For

1

QVGA (320×240)

Fastest transfer, lowest data usage

2

VGA (640×480)

Good balance of quality and speed (default)

3

SVGA (800×600)

Better detail

4

XGA (1024×768)

High detail

5

SXGA (1280×1024)

Very high detail

6

UXGA (1600×1200)

Maximum detail, highest data usage


Battery & Power Settings

Setting
Range
Default
Description

Battery Type

5Ah / 10Ah

Varies by region

Must match installed battery for accurate level estimation.

Battery Alerts

On/Off

On

Enables low battery notifications at 20% and 10% levels.

Power-Off Voltage

7.0–12.0V

9.6V

Voltage threshold below which the trap automatically hibernates.

Battery Alert Thresholds

Alert Level
Default Voltage
Description

20% Warning

10.4V

Low battery warning sent

10% Critical

~9.5V

Critical battery warning sent

Auto Power-Off

9.6V

Trap enters hibernation to protect battery

Reset Threshold

11.0V

Battery must reach this level to clear low-battery flags


Temperature Alert Settings

Setting
Range
Default
Description

Temperature Alerts

On/Off

On

Enables alerts when temperature exceeds thresholds.

High Temperature Limit

Configurable

45°C (113°F)

Alert sent if internal temperature rises above this.

Low Temperature Limit

Configurable

-10°C (14°F)

Alert sent if internal temperature falls below this.

Temperature Alert Interval

0–48 hours

8 hours

Minimum time between temperature alerts. Set to 0 to disable repeat alerts.


GPS & Location Settings

Setting
Range
Default
Description

Location (GPS)

On/Off

On

Enables periodic GPS location updates.

GPS Interval

Configurable

8 hours

How often the trap updates its GPS position. Longer intervals save battery.

GPS Behavior Details

  • First fix delay: 5-minute initial delay after boot before first GPS acquisition

  • Acquisition timeout: 3 minutes for first fix, 2 minutes for subsequent fixes

  • Fix requirements: Minimum 5 satellites, 3D fix required for valid position

  • Automatic updates: GPS automatically triggered on capture events


Accessory Port Settings

Setting
Range
Default
Description

Accessory

On/Off

Off

Enables the 12V accessory port for external devices.

Accessory Timing

0–30,000ms

Duration the accessory port remains powered when activated.

The 12V accessory port can power external devices like dispensers, pumps, or other add-on hardware.


Capture Alert Settings

Setting
Range
Default
Description

Capture Alerts Interval

0–48 hours

8 hours

Minimum time between capture alert notifications. Prevents repeated alerts for same capture.


Hardware & Feedback Settings

Setting
Options
Default
Description

User Beeps

On/Off

On

Audible beeps for button presses, state changes, and feedback.

Enhanced Door Closing

On/Off

Off

Performs additional open/close cycle to ensure door is fully locked.

Units

Metric/Imperial

Imperial

Display units for distance and temperature throughout the app.


Image Cropping Settings

These settings remove portions of the image before processing. Values are percentages of the image dimension.

Setting
Range
Default
Description

Left Crop

0–50%

0%

Removes left portion of image

Right Crop

0–50%

0%

Removes right portion of image

Top Crop

0–50%

0%

Removes top portion of image

Bottom Crop

0–50%

0%

Removes bottom portion of image


Settings Locations

Settings are accessible in different locations:

Location
Settings Available

App → Trap → Settings → More Settings

Most user settings

App → Trap → Settings → Advanced Settings

Temperature alerts, image cropping

App → Account

Notification preferences, units


Tips for Optimal Settings

For Maximum Battery Life

  • Set GPS Interval to 8+ hours

  • Use Camera Quality level 1–2

  • Set Camera Time Lapse to 6+ hours or disable

  • Reduce Maximum IR Brightness if images are overexposed

For Best Image Quality

  • Use Camera Quality level 4–6

  • Adjust Dark Lux Threshold based on your deployment (lower = earlier IR activation)

  • Fine-tune IR brightness settings for your environment

For Fastest Response

  • Keep GPS enabled for accurate location on captures

  • Enable Pre-Capture Alerts to see animals approaching

  • Use shorter Capture Alert Intervals if monitoring actively